A hospital car park runs 24 hours a day and serves staff on long shifts, outpatients on short visits and families who stay unpredictably. Each group needs a different charging setup.

Who Parks at a Hospital

Plan for Each Group Separately.

GroupTypical stayWhat fits
Day and night shift staff8–12 h7 kW AC on staff-only bays with card access
Outpatients1–3 h11–22 kW AC close to outpatient entrances
Visitors and families30 min to several hoursAC with time limits, plus a compact DC charger for short stays
Hospital fleet and patient transportBetween tripsAC overnight, DC for quick top-ups between runs
Emergency department—No charging bays in ambulance lanes or emergency drop-off areas
Range Per Visit

How Much Range Do Visitors and Staff Add While Parked?

Hospitals serve short visits, long outpatient appointments and 8- to 12-hour staff shifts. Match charging power to each group.

Short answer: in a 2-hour visit, an 11 kW AC charger adds about 122 km (76 miles), and in one hour a 22 kW DC charger adds about 122 km (76 miles). Staff on 8- to 12-hour shifts can fully recharge on lower-power AC, so many hospitals put AC in staff lots and a few faster chargers near visitor entrances.
Charging Power1-Hour Visit2-Hour Visit4-Hour VisitGood Fit For
7.4 kW ACSingle-phase wallbox≈ 41 km / 25 mi≈ 82 km / 51 mi≈ 164 km / 102 miStaff parking for long shifts
11 kW ACThree-phase, or 11.5 kW Level 2 in North America≈ 61 km / 38 mi≈ 122 km / 76 mi≈ 244 km / 152 miVisitor and outpatient bays
22 kW ACThree-phase wallbox≈ 122 km / 76 mi*≈ 244 km / 152 mi*Near full for most cars†Fleet vehicles that accept 22 kW AC
22 kW DCCompact DC≈ 122 km / 76 mi≈ 244 km / 152 miNear full for most cars†Short visits and patient transport turnarounds

Estimates assume average consumption of 18 kWh per 100 km (about 3.5 miles per kWh), and do not include charging losses; real results vary with the vehicle, temperature and battery level. *AC charging speed is capped by the vehicle's onboard charger. Many EVs accept 11 kW AC at most, so a 22 kW AC charger gives those cars 11 kW. DC charging bypasses the onboard charger. †Most EV batteries hold roughly 50–80 kWh, and DC charging slows down as the battery fills.

Site Planning

What Hospitals Must Get Right.

Keep emergency routes clear

Charging bays and cables must never sit in ambulance lanes, emergency drop-off zones or fire access routes.

Accessible bays matter more here

Many visitors have limited mobility. Follow local guidance on accessible charging bays, such as PAS 1899 in the UK or the US Access Board guidance.

Separate from critical power

Chargers should be fed from the general supply, not essential or life-safety circuits. Agree this with your estates and engineering team.

Light and secure for night shifts

Night staff walk to their cars in the dark. Light the bays well and place them within CCTV coverage.

Staff bays away from visitors

Staff park for whole shifts. A separate staff charging area with card access keeps visitor bays free.

Clear wayfinding

Visitors are often stressed and unfamiliar with the site. Signpost the charging area from the entrance.

Operations

Run It Around the Clock.

Staff access and pricing

Give staff RFID cards or app access with their own tariff, separate from visitor pricing.

Time limits for visitor bays

A time limit and an idle fee after charging ends keep visitor bays available through the day.

Fault alerts at any hour

Chargers report faults over OCPP. Agree who receives alerts at night and at weekends.

Schedule fleet charging

Charge fleet vehicles overnight when demand is low, and keep one fast option for vehicles that must go out again quickly.

Recommended Hardware

Chargers That Fit Hospital Sites.

Specifications from our current product catalogue. Certificates are listed per model in every quote.

Type 2 markets · single-phase

EV-ACT3204E wallbox

  • 7 kW, 32 A, 230 V single-phase
  • Tethered Type 2 cable, 5 m or 7 m
  • RFID card, app and plug-and-charge start
  • Wi-Fi and Bluetooth, 4G optional

Best for staff bays on a single-phase supply.

Type 2 markets · three-phase

EV-ACT1602PE wallbox

  • 11 kW, 16 A, 380–400 V three-phase
  • Tethered Type 2 cable, CEE 5-pin plug
  • RFID card, app and plug-and-charge start
  • Wi-Fi and Bluetooth, 4G optional

Best for staff and outpatient bays on a three-phase supply.

Type 2 markets · three-phase

EV-ACT3204PE wallbox

  • 22 kW, 32 A, 380–400 V three-phase
  • Tethered Type 2 cable, CEE 5-pin plug
  • RFID card, app and plug-and-charge start
  • IP66

Best for outpatient bays where visits last 1–3 hours.

DC · all markets

EV-RHDC30K-L compact DC charger

  • 22 kW DC output, single tethered connector
  • 380–415 V three-phase input
  • OCPP 1.6J, RFID card and app start
  • IP54, 5 m cable, floor-standing

Best for short visitor stays and fleet top-ups.

North America

EV-ACT3204U / EV-ACT3204T

  • 32 A, 7.68 kW, 240 V
  • J1772 (U) or NACS (T), 25 ft cable
  • NEMA 14-50 plug
  • App and plug-and-charge start

Best for staff bays in the US and Canada.

North America

EV-ACT4001U / EV-ACT4001T

  • Up to 40 A, 9.6 kW, 208–240 V
  • J1772 (U) or NACS (T), 25 ft cable
  • NEMA 14-50 plug, needs a 50 A breaker
  • NEMA 4 / IP66, Wi-Fi and Bluetooth

Best for outpatient and visitor bays in North America.

Final circuit sizing and permits must follow your local electrical code and be confirmed by a licensed electrician.

Market Requirements

Rules to Check Before You Buy.

Chargers that are open to the public face extra rules on safety listings, connectors and payment. Use this checklist for your region.

United States & Canada

  • Safety listing from a recognized testing lab (UL, ETL or CSA mark) for the exact model
  • Installation to NEC Article 625 in the US or the Canadian Electrical Code
  • Connectors: SAE J1772 or NACS (SAE J3400) for AC; CCS1 or NACS for DC
  • Check local accessibility rules for public charging bays

European Union

  • CE marking, with chargers built to IEC 61851
  • Connectors: Type 2 for AC, CCS2 for DC
  • Under AFIR, publicly accessible chargers must allow ad-hoc payment: below 50 kW by card reader, contactless device or secure QR payment; 50 kW and above by card reader or contactless device
  • Billing per kWh may require calibration-law-compliant metering in some countries, such as Germany

United Kingdom

  • UKCA or CE marking
  • Connectors: Type 2 for AC, CCS2 for DC
  • Under the Public Charge Point Regulations 2023, new public charge points of 8 kW and above must accept contactless payment
  • Public charging prices must be shown clearly in pence per kWh
Buyer tip: ask every supplier, including us, for the certificate that covers the exact model, connector and voltage you are ordering, not just a logo in a brochure.
Access Planning

Visitors, Staff and Fleet.

Hospitals usually serve three groups with very different needs. Plan access, power and pricing for each.

Visitors & Outpatients

Best for: Short and medium stays near main entrances.

How it works: Pay-per-use by app or a supported payment method, with time limits so bays keep turning over.

Watch out for: Accessible bays, clear signage and good lighting for evening visits.

Staff

Best for: Long shifts in dedicated staff lots.

How it works: RFID or app access for staff, with charging free or billed at cost, and lower power shared across more bays.

Watch out for: Shift changeovers. Notifications and idle fees help free bays for the next shift.

Hospital Fleet

Best for: Patient transport, logistics and service vehicles.

How it works: Reserved bays on a separate access list, with session reports for each vehicle.

Watch out for: Making sure fleet vehicles are charged before the next shift starts.

Faster Proposals

Send Us These 6 Details for a Tailored Plan.

This helps our engineers recommend the right configuration for your site faster.

1Country and city of the hospital
2Site plan of visitor, staff and fleet parking
3Electrical supply available at each lot
4User groups to serve and bays for each
5How charging will be paid for
6IT and security requirements for connected devices
Send Your Site Details →
Common Questions

Hospital EV Charging — Frequently Asked Questions.

Where should chargers go on a hospital site?

Away from ambulance lanes, emergency drop-off and fire access routes. Put staff chargers in staff areas, outpatient chargers near outpatient entrances, and make sure at least some bays are accessible and well lit.

Can EV chargers affect a hospital’s critical power?

They should not be connected to essential or life-safety circuits. Feed chargers from the general supply and use load management so charging slows down when building demand is high. Your estates team and electrician should confirm the design.

Should staff pay for charging?

That is a policy decision. Many hospitals give staff their own tariff through RFID cards or the app, separate from visitor pricing, so the costs are clear either way.

How do we stop visitors blocking charging bays?

Set a time limit, show it on signs and add an idle fee that starts when charging ends. Fault and session data show whether limits need adjusting.

Do hospitals need DC fast chargers?

Not for staff, who park for whole shifts. A compact DC charger is useful for short visitor stays and for fleet vehicles that need a quick top-up between trips.

Are accessible charging bays required?

Requirements depend on your country. Even where they are not mandatory, guidance such as PAS 1899 in the UK and the US Access Board guidance explains how to make bays usable for disabled drivers.