EV-ACT3204E RCD Requirements: Type A, Type B and DC Detection

The EV-ACT3204E's listing claims no built-in RCD or DC detection. Type A, Type B and 6 mA DC detection explained — and why the choice is your installer's.

EVDANCE Insights · EV Charging Guides

For this wallbox, the RCD requirement is decided on the circuit side, not read off the product page. The EV-ACT3204E‘s listing states no built-in RCD and no DC fault detection, so an installer specifies the protective device for its dedicated circuit under local wiring rules. The Type A or Type B choice turns on one question: where smooth DC fault current is detected — in the charger, or in the RCD itself.

Key Takeaways

  • This model’s listing claims no built-in RCD or DC detection — plan on circuit-side protection until confirmed otherwise.
  • Type A sees AC and pulsating DC; Type B adds smooth DC; 6 mA DC detection can cover the DC gap beside a Type A.
  • On a hardwired install the RCD is selected when the dedicated circuit is designed — by your installer, under your local rules.
  • If the installer specifies a device or board work, that answer outranks any datasheet assumption.
EVDANCE EV-ACT3204E 22 kW three-phase wallbox
The listing covers power, connector and control — no RCD claim.

The Three Terms, in Brief

An RCD disconnects the supply when current leaks to earth. EV charging complicates that job: a car’s onboard charger can produce smooth DC fault current, which can blind an ordinary RCD. Our explainer on RCD protection, Type A, Type B and 6 mA DC detection works through the three terms in full.

DeviceWhat it detectsIts place in an EV circuit
Type A RCDAC and pulsating DC residual currentSufficient for EV charging only when smooth DC is dealt with separately
Type B RCDAC, pulsating DC and smooth DC residual currentCovers the DC fault case in the RCD itself
6 mA DC detectionSmooth DC residual current at the 6 mA threshold, disconnecting the supplyA detection function, often built into a charger, covering the DC gap beside a Type A

Read This Model’s Listing Literally

Product listings are claims documents: what is not written is not promised. The written claims here are the 22 kW three-phase output, Type 2 cable or socket, RFID and app control, IP65/IP66 housing and CE mark. No RCD type and no DC detection appears among them. Two consequences follow:

  • Plan as if DC detection is not built in. Until the manual — or the manufacturer in writing — states a detection function, assume the circuit must provide the whole answer.
  • The manual is an installation document. On a hardwired wallbox, the manual’s required upstream protection is what your installer works to — get it before the circuit is designed.

The Decision Your Installer Actually Makes

A hardwired wallbox differs from a portable on an existing socket: nothing is inherited, and the installer selects the protective device as part of the new circuit’s design:

QuestionIf the answer is yesIf the answer is no
Is 6 mA DC detection confirmed in the manual or in writing?A Type A RCD upstream is the usual pairingThe RCD itself must cover smooth DC — the Type B route
Do local wiring rules specify a device for EV circuits?The installer’s specification follows them
Is the home’s earthing or board unusual?The installer adjusts the design

One rule outranks the table: if your installer specifies a device or board work, that stands — over any assumption from a forum, a video, or another charger’s manual. The same protection job carries the GFCI name in North America; see our explainer on whether an EV charger needs GFCI protection.

The Charger Behind the Question

The EV-ACT3204PE is a 22 kW wallbox for three-phase supplies — 32 A per phase at 380–400 V — hardwired, with a tethered Type 2 cable, RFID and app control, an IP66 housing and a CE mark, backed by EVDANCE’s 3-year standard warranty. Nothing in that specification is a protection claim: the RCD conversation belongs before installation, between you, the manual and a licensed electrician. If the manual is unclear on the required upstream device, ask EVDANCE through the contact page and keep the answer.

Home EV charger installation
On a hardwired install, the protective device is chosen when the circuit is designed.

Frequently Asked Questions

Does the EV-ACT3204E have a built-in RCD?

Not stated. Neither the listing nor the specification claims an RCD or DC fault detection for this model. Treat both as circuit-side until the manual or the manufacturer confirms otherwise in writing.

So which do I need — Type A or Type B?

It depends on where DC detection lives and on local rules — the installer’s specification, not a product-page answer. Confirmed DC detection points to Type A; without it, the RCD must cover smooth DC: Type B.

My consumer unit already has a Type A RCD. Can the installer just use that?

Possibly, but do not assume it: whether an existing device can serve a new dedicated circuit — and the DC detection question — is the installer’s call under local rules. Ask at the design stage.

Related Reading

Sources & Standards

EVDANCE · EV Charger Manufacturer

Looking for a reliable EV charger supplier?

Portable EV chargers and wallbox home chargers for distributors, installers and brands. Tell us your market and we will reply with a quote.

  • OEM / ODM from 50 units
  • 3-year standard warranty
  • FOB / DDP shipping worldwide
Share the Post:

Related Posts

0