Copper or Aluminium Wire for the EV-ACT5006T’s 48A Circuit? What Each Metal Changes

Wall-mounted EVDANCE home EV charger installed on a house exterior beside a driveway
A 48 A charger needs wire rated for a 60 A circuit. Copper is the standard run; aluminium works at a larger size. What the metal choice changes for the EV-ACT5006T.

EVDANCE Insights · EV Charging Guides

A 48 A charger needs wire rated for a 60 A circuit, because the National Electrical Code treats EV charging as a continuous load and sizes the breaker at 125% of the charger’s current. For that circuit, copper is the standard choice, and 6 AWG copper is the typical run. Aluminium can do the same job at a larger size. The metal changes the cable size, the terminations and the quote — here is how it plays out for the EV-ACT5006T 48A Level 2 wall charger.

Key Takeaways

  • A 48 A charger needs conductors rated for a 60 A circuit; the metal is chosen inside that requirement.
  • Copper is the default: 6 AWG typical, standard terminations, no special hardware.
  • Aluminium works at a larger size, and its terminations — not the cable — decide whether the job is a good one.
  • Old aluminium branch wiring in an existing home is a different subject from a new aluminium run; do not mix them up.

The Circuit Comes First, the Metal Second

Wire size follows the breaker, not the charger badge. A 48 A charger on a 60 A breaker needs conductors rated for that 60 A circuit, whatever they are made of. Our general guide to what size wire an EV charger needs gives the full copper chart; the breaker sizing guide walks through the 125% rule. The metal decision comes after those numbers are fixed: both metals must meet the same rating, at different sizes. The ACT5006T is set to its circuit at installation, so charger, breaker and wire are matched as one job.

Wall-mounted EVDANCE home EV charger installed on a house exterior
A finished 48 A install — the wire decision happened earlier, inside the wall.

Copper vs Aluminium, Side by Side

QuestionCopperAluminium
Size for a 60 A rating6 AWG is the typical runA larger gauge for the same rating; the exact size is the electrician’s call under the NEC
Where you usually meet itBranch circuits like this charger runService entrances and feeders; some larger circuits
TerminationsStandard breaker and charger lugs are rated for itNeeds aluminium-rated lugs and careful termination; the connection is the weak point
Cost shapeMetal costs more per metreMetal usually costs less, but fittings and labour can narrow the gap

Copper is the default for practical reasons: it reaches the rating at a smaller size, it fits standard breaker and charger terminals without special hardware, and electricians work with it daily. Aluminium conducts less per unit of area, so the conductor grows to carry the same current — which is why it appears most often where the run is big and the material saving is real.

Where aluminium earns its caution is at the ends. Its terminations depend on lugs rated for the metal, the correct compound and properly torqued connections, because the joint is where aluminium installations succeed or fail. A quote in aluminium should name that hardware; if it does not, ask.

The Aluminium Already in Older Homes Is a Different Question

A new aluminium run, chosen and terminated for this circuit, is not the same thing as the aluminium branch wiring fitted in some homes decades ago. That older wiring raises questions about existing small circuits and their connections, and deserves an electrician’s look before any charger is added. A correctly sized, correctly terminated aluminium feeder installed today is a separate, legitimate use of the metal. The two share a word and nothing else.

The Charger at the End of the Run

EV-ACT5006T 48A NACS Level 2 wall charger
The EV-ACT5006T: 48 A, NACS, hard-wired or NEMA 14-50P, with a 7.6 m cable.

The EV-ACT5006T delivers up to 48 A (11.5–12 kW), hard-wired or through a NEMA 14-50P plug, with a 7.6 m NACS cable and IP65/IP66 sealing. Hard-wired, it sits on the 60 A circuit this article is about; plugged in, on the receptacle’s 50 A circuit, with the same logic at that rating — our hardwired vs plug-in comparison covers that choice. Either way, the metal decision changes the run, not the charger: tell your electrician which connection you want, and let them spec the metal to suit. The full EVDANCE product range shows the other ratings.

Frequently Asked Questions

Is aluminium wire allowed for a 48 A charger circuit?

Yes, when sized and terminated for the 60 A circuit under the NEC: conductors rated for the load, lugs rated for aluminium, termination done to the lug maker’s spec. Your electrician confirms all three.

Why do two quotes for the same charger use different metals?

Because installed price is metal plus fittings plus labour: aluminium lowers the material line but adds termination hardware and care; copper costs more as a metal, less as a job. Ask each quoter which metal and size the price assumes.

Can I specify the wire myself to save money?

Sizing and termination are licensed work, and the wrong call fails inspection or worse. Ask for the run priced both ways and choose between two compliant options instead.

Related Reading

Sources & Standards

EVDANCE · EV Charger Manufacturer

Looking for a reliable EV charger supplier?

Portable EV chargers and wallbox home chargers for distributors, installers and brands. Tell us your market and we will reply with a quote.

  • OEM / ODM from 50 units
  • 3-year standard warranty
  • FOB / DDP shipping worldwide
Share the Post:

Related Posts

0